Brand Name : AIP

Model Number : AIP965**

Place of Origin : China

MOQ : 1 set

Price : Negotiable

Payment Terms : L/C, T/T

Supply Ability : 50 Sets per month

Delivery Time : 15 working days

Packaging Details : Wooden case

Product : Household Appliances Electrical Safety Testing System/Safety Tester

Variable frequency inverter : 2KVA or 5KVA

Configuration : 2U IPC

Monitor : 19" LCD

Power supply : 220V

Customized function : Acceptable

Contact Now

Household Appliances Electrical Safety Testing System/Safety Tester

1. Product introduction

This series of safety testing system are mainly applied to different home appliances manufacturers, home appliances safety certificate authorities and scientific research institutions.

2. Test items

  • AC Hi-pot
  • Insulation resistance
  • Grounding resistance
  • Leakage current
  • Low voltage start-up
  • No-load power

3. Standard accessories

Power cord×1, foot switch×1, 30A testing pliers×2, testing box×1, power input line×1, protective tube×1, user manual×1, alarm light×1

4. Dimension

600W×1840H×600Dmm The height includes reels and alarm light.

5. ​Parameters specification

AC Hi-pot
Output voltage setting range/precision AC 200~5000V ±(1.5%×setting value+5 words) static
Breakdown current measurement range/precision 0.10~99.99mA ±(1.5%×display value+5 words)
Breakdown current preset alarm Max.: 0.10~99.99mA; Min.: 0.00~5.00mA
Test time range/resolution 1~300s 1s/step
Arc detection(optional) 1~9 level(9 is the most sensitive level)
DC Hi-pot
Output voltage setting range/precision DC 200~6000V ±(1.5%×setting value+5 words)
Breakdown current measurement range/precision 0.10~10.00mA ±(1.5%×display value+5 words)
Breakdown current preset alarm Max.: 0.10~10.00mA; Min.: 0.00~5.00mA
Test time range/resolution 1~300s 1s/step
Insulation resistance
Output voltage setting range/precision DC 200~1000V ±(3%×reading+5 words)
Insulation resistance measurement range/precision 1~2000MΩ ≤100MΩ:±(5%×display value+3 words) >100 MΩ:±(8%×display value+8 words)
Insulation resistance alarm setting range Max.: 0~2000MΩ; Min.: 1~2000MΩ
Test time range/resolution 1~300s 1s/step
Grounding resistance
Grounding current output range/precision AC 5.0~30.0A ±(1.5%×setting value+0.2A)
Grounding resistance measurement range/precision 10.0~600mΩ ±(1.5%×display value+3mΩ)
Grounding resistance alarm setting range Max.: 5~10A:10.0~600mΩ;11~25A:10.0~300mΩ;26~30A:10.0~200mΩ;
Min.: 0.0~100mΩ
Test time range/resolution 1~300s 1s/step
Leakage current
Output voltage 1.06 times rated voltage, built-in variable frequency inverter
Leakage type setting Dynamic leakage, static leakage, optional equipped with 3 types of body network, which can be customized and switched freely.
Output voltage setting range/precision AC 50~280V ±(0.5%×display value+2 words)
Leakage current setting range/precision 0.05~20.00mA ±(1.5%×display value+10uA)
Leakage current setting alarm range Max.: 0.05~20.00mA; Min.: 0.01~5.00mA
Test time range/resolution 1~300s 1s/step
No-load power
Output voltage 1.0 times rated voltage, built-in variable frequency inverter
Output voltage measurement range/precision AC 50~280V ±(0.2%×display value+0.05%×measuring range)
Output current measurement range/precision AC 0.20~30.00A ±(0.2%×display value+0.05%×measuring range)
Active power measurement range/precision 30~6000W ±(0.2%×display value+0.05%×measuring range)
Power setting alarm range Max.: 3~6000W ; Min.: 0~6000W
Test time range/resolution 1~300s 1s/step
Low voltage start-up
Output voltage 0.85 times rated voltage, built-in variable frequency power
Output voltage measurement range/precision AC 50~280V ±(0.5%×display value+2 words)
Start-up current measurement range/precision AC 0.20~30.00A ±(0.5%×display value+2 words)
Current setting alarm range Max.: 0.20~30.00A ; Min.: 0.00~25.00A
Test time range

1~300s 1s/step

6. Product reference picture

Household Appliances Electrical Safety Test Equipment 2U IPC Configuration


Product Tags:

electrical safety test equipment

      

electrical safety analyzer

      

Household Electrical Safety Test Equipment

      
Quality Household Appliances Electrical Safety Test Equipment 2U IPC Configuration wholesale

Household Appliances Electrical Safety Test Equipment 2U IPC Configuration Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Qingdao AIP Intelligent Instrument Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)